Chilled Water Multi-DENCO®

Multi-DENCO® close control units in the chilled water version (C-version) are suitable for the air conditioning of server rooms, small data centres, laboratories, technical rooms or archive rooms that have year-round air conditioning requirements.

The devices offer an elevated level of flexibility, variety and efficiency and are appealing due to high-quality components such as EC fans, powerful heat exchangers and a modern control system.

  • 7-unit sizes from 10 kW to 130 kW
  • Water-based cooling without refrigerant in the installation room
  • Available as CombiCool version with 2 separate water circuits
  • Selectable with 2-way, 3-way or pressure-independent 2-way control valves (PICV)
  • Highly efficient speed-controlled EC fans
  • Upflow and Downflow configurations available
  • Large heat exchangers in standard or high-performance design
  • Electric heating and steam humidifier as options
  • Energy monitoring, automatic power transfer switch (ATS) and many other electrical options available
  • Internal network solution (DENCONet) for controlling several devices in a group, as well as connection to building management systems (BMS) available
  • Advanced controls package with 4.3″ touchscreen
    Ideal for connection to a FläktGroup chiller with free cooling (FGFC/ GLFC
  • series)
  • Operation with water or water-glycol mixtures possible

Brug for hjælp?

Få rådgivning og support til projekter

Multi-DENCO® close control units as chilled water version represents a particularly flexible and future-proof system, since a connection to a wide variety of cooling systems is possible via the chilled water circuit. As a system solution, FläktGroup offers suitable chillers for indoor (FGWC/GLWC) or outdoor installation (FGAC), as well as chillers with an integrated free cooling function (FGFC/GLFC). Furthermore, heat recovery can be realised with the help of 4-pipe heat pumps HeaMo (FGAS), so that the waste heat from the cooling process can be used as heating energy for space heating free of charge.

A major advantage is that no refrigerant is used in the installation room since the energy is transported solely via the chilled water circuit. This means that the choice of refrigerant and the refrigerant charge depends solely on the independent refrigeration system, which is usually installed outside. In addition, chillers and Multi-DENCO® close control units of the C-version can be replaced independently of one another as part of retrofit measures.

Two variants are available:

  • C-Version: Chilled Water with Standard or High-Performance Heat Exchanger (4 or 6 rows)

The units are available with 3-way, 2-way or pressure-independent 2-way valves for the chilled water circuit.

  • C-Version + CombiCool: Dual Chilled Water Circuits

With this system 1 indoor unit can be connected to 2 chilled water sources. The primary circuit is typically receiving chilled water (CW) from a chiller, but it can also be used in conjunction with dry coolers or similar heat reject systems for lower cost cooling or free cooling. The backup circuit is then connected to a chiller for reliability and redundancy. Either during maintenance or an unexpected fault of the primary circuit, the Multi-DENCO® unit can independently and autonomously change to the backup circuit to ensure operations can continue seamlessly. As soon as possible, the device controller automatically switches back to the primary circuit. 3-way valves are used.

Ingen produktegenskaber fundet.

Andre relevante produkter

Hydro-DENCO® High Capacity CRAH

Hydro-DENCO® are Computer Room Air Handlers (CRAH) for cooling server rooms, medium size to hyper scale data centres, UPS or other technical rooms that have year-round air-cooling requirements.
Læs mere

Fresh Heaven MAXX O POWER LAMINAR AIRFLOW UNIT

Fresh Heaven MAXX O POWER ensures full filtration of air supplied by an air-handling unit and mixed with recirculated clean room air, thereby protecting the operating theater area around a patient.
Læs mere

Fresh Heaven MAXX O LAMINAR AIRFLOW UNIT

Fresh Heaven MAXX O ensures full filtration of air supplied by an air-handling unit protecting the operating theater area around a patient.
Læs mere

Fresh Heaven MAXX LAMINAR AIRFLOW UNIT

Fresh Heaven MAXX LAMINAR AIRFLOW UNIT (LAF) is designed for industry purposes. It provides product or process protection by supplying a low-turbulent clean air supply, minimizing the risk of contaminants from surrounding areas. Size upon Customer’s demands Air delivered by AHU (FHM) or recirculation mode with power module (FHM P) H13, H14 or U15 filters with U-shaped or fluid gasket Casing in stainless-steel / steel in RAL 9010, height 450 mm (FHM) / 550 mm (FHM P) Various outlets (perforated stainless-steel / steel in RAL 9010, polyester fabric) Equipped with autonomous automatics (local control via Siemens LOGO! panel)
Læs mere

Søg efter produkt

Kontakt

Troels Mortensen

Adm. direktør, AHU Pharma

Du er også velkommen til at udfylde vores kontaktformular, så vender vi tilbage hurtigst muligt. Vi glæder os til at høre fra dig!

Kontakt

Jesper Hofmann Larsen

Kølebafler, Spjæld

Du er også velkommen til at udfylde vores kontaktformular, så vender vi tilbage hurtigst muligt. Vi glæder os til at høre fra dig!

Kontakt

Morten Schjoldager

Fancoils, Varmeventilatorer, Lufttæpper, Renrum

Du er også velkommen til at udfylde vores kontaktformular, så vender vi tilbage hurtigst muligt. Vi glæder os til at høre fra dig!

Kontakt

Glennie Sørensen

Service, Indkøb, Logistik

Du er også velkommen til at udfylde vores kontaktformular, så vender vi tilbage hurtigst muligt. Vi glæder os til at høre fra dig!